Problem 4.5

The 10kW resistor is used to decrease current level (Widlar current source). With this configuration, we get a lower VBE value for Q2 than for Q1.

To investigate b effects, we assume b effect of Q2 is small; of course, we need to validate this assumption after solving this problem, that is that the current in Q2 is much smaller than for Q1.

We also know that neglecting the base current for Q1 results in a percent error of 1/(1 + 1 / b ) which is roughly 1% error. Therefore, we will ignore b effects throughout the remainder of this problem.

Therefore, Iin = Is eV / UT = (15V - V ) / 20kW, where V is the middle node of the current source.  Note, we have the same problem as in Prob 4.1; therefore we get V.

Then writing a KVL loop including VBE of Q1 and Q2, and the 10kW resistor, we get

Iout = (UT / 10kW) ln( Iin / Iout ) = 2.5mA ln( Iin / Iout ).

Knowing Iin = , we get Iout by iteration as .